Description
Technical Parameters
advantage
- Easy to use
- No equipment required
- High sensitivity and specificity
- Fast results at 10 minutes
Summary
D-dimer is a biomarker that globally indicates the activation of hemostasis and fibrinolysis. It is a degradation product of fibrin, which is produced when cross-linked fibrin is degraded by plasmin-induced fibrinolytic activity. Fibrin D-dimer, a marker of on-going fibrin formation and degradation, is the most commonly used clinical assay for the detection of activation of the coagulation system. As D-dimer plasma levels are elevated after clot formation, the measurement of D-dimer is routinely used in conjunction with clinical parameters in the initial assessment of suspected acute VTE. Elevated D-dimer levels measurement provides prognostic indications for a variety of conditions, including venous thromboembolism, disseminated intravascular coagulation, cardiovascular disease, infectious diseases, and cancer. The D-Dimer Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid test to qualitatively detect the presence of D-Dimer in whole blood, serum or plasma specimen. The test utilizes monoclonal antibodies to selectively detect elevated levels of D-Dimer in whole blood, serum or plasma. The minimum detection level is 500 ng/mL.
Convenient Procedure

1. Let the pouch come to room temperature before you open it. Take the test cassette out of the sealed pouch and use it within an hour.
2. Put the cassette on a clean, flat surface.
For Serum or Plasma samples:
- Hold the dropper straight up and put 1 drop of serum or plasma (about 25μL) into the sample well of the test cassette, then add 1 drop of buffer (about 40μL) and start the timer. Check the illustration below.
For Venipuncture Whole Blood samples:
- Hold the dropper straight up and put 2 drops of whole blood (about 50μL) onto the sample area, then add 1 drop of buffer (about 40μL), and start the timer. Check the illustration below.
For Fingerstick Whole Blood samples:
- To use a capillary tube: Fill the capillary tube and move about 50μL of fingerstick whole blood sample to the sample area of the test cassette, then add 1 drop of buffer (about 40μL) and start the timer. Check the illustration below.
Look for the colored line(s) to show up. Read the results after 5 minutes. Don't read the results after 20 minutes.
Accurate Results

Hot Tags: d-dimer rapid test, China d-dimer rapid test manufacturers, suppliers, factory, HbsAg Rapid Test Device, Adv Rapid Test, Adenovirus Combo Rapid Test Cassette, D Dimer Rapid Test, Dengue IgG Test Device, BNP Rapid Test
Previous
NT-proBNP Rapid TestNext
CKMB Rapid TestSend Inquiry